The H8C shearbeam load cell is a Class 3 and OIML R60 approved electrical weight measuring device that offers total protection against liquids.
- Alloy steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, with 4 core screened cable suitable for all kinds of environment.
- Single shear beam, easy for installation, suitable for electronic platform scales, hopper scales and other electronic weighing devices.
- Safe and anti-explosive product, can be used in atrocious environment and hazardous areas
- Low profile.
- With OIML, NTEP approval.
Zemic’s H8C shear beam load cells are highly-versatile, easy-to-install weighing scale load cells ideal for monitoring and converting force into a measurable output. The H8C load cell series is a highly popular and versatile product that can be used within multiple components with medical, automotive and agricultural machinery installations.
The H8C series is constructed from durable nickle-plated alloy steel with IP67-rated protection against dust and water ingress, making them suitable for use in harsh industrial environments. This load cell is supplied with a 4m (4 core screened cable) length.
Accuracy class | OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | |||
Output sensitivity ( = FS ) | mV/V | 3.0 ± 0.003 | ||||
Maximum capacity ( Emax ) |
t |
0.1, 0.25, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 5, 10 |
0.1,
0.25, 0.5, 0.75, 1, 1.5, 2, 2.5 |
3, 5, 10 |
||
Max. number of load cell intervals | nLC | 3000 | 4000 | 5000 | ||
Ratio of min. LC verification interval | Y = Emax / vmin | 10000 | 15000 | 20000 | 18000 | |
Combined Error | %FS | ≤± 0.023 | ≤± 0.0175 | ≤± 0.014 | ||
Minimum dead load | Of Emax | 0% | ||||
Safe overload | of Emax | 150 % | ||||
Ultimate overload | of Emax | 300 % | ||||
Zero balance | of FS | < ± 1.0 % | ||||
Excitation, recommended voltage | V | 5 ~ 12 | ||||
Excitation maximum | V | 18 | ||||
Input resistance | Ω | 350 ± 3.5 | ||||
Output resistance | Ω | 350 ± 3.5 | ||||
Insulation resistance | MΩ | ≥5000 ( at 50VDC ) | ||||
Compensated temperature | °C | -10 ~+40 | ||||
Operating temperature | °C | -35 ~ +65 | ||||
Storage temperature | °C | -40 ~ +80 | ||||
Element material | Nickel plated alloy steel | |||||
Ingress Protection (acc. to EN 60529) | IP67 | |||||
Recommended torque on fixation | Nm | M12: 75 | M18:500 | M24:750 | ||
ATEX classification (optional) | II1G Ex ia II1C | II1D Ex iaD 20 T73°C | II3G nL IIC T4 | |||