Brand:

CPA SERIES LOW PROFILE COMPRESSION LOAD CELLS

Categories:

Call for price

[posbadges]

This product is currently out of stock and unavailable.

Stainless steel compression load cells suitable for extremely harsh environments and high temperatures.

CAPACITIES (kg): 150, 300, 500, 1000, 2000, 3000, 5000, 7000, 10000, 20000, 30000, 50000.

OIML R60, C3 precision class from 2000 a 10000kg.

Stainless steel. IP68 protection.

GET QUOTATION

Brand:

CPA SERIES LOW PROFILE COMPRESSION LOAD CELLS

Categories:

Call for price

[posbadges]

This product is currently out of stock and unavailable.

Stainless steel compression load cells suitable for extremely harsh environments and high temperatures.

CAPACITIES (kg): 150, 300, 500, 1000, 2000, 3000, 5000, 7000, 10000, 20000, 30000, 50000.

OIML R60, C3 precision class from 2000 a 10000kg.

Stainless steel. IP68 protection.

[showcdownloadbuttoninspp]
[showmdownloadbuttoninspp]
GET QUOTATION
[woocommerce_variations_table]

MAIN FEATURES

  • CAPACITIES from 150 to 10000 kg
  • OIML C3 CLASS, from 2000 to 10000 kg
  • LOW PROFILE
  • GREAT RESISTANCE TO LATERAL FORCES
  • STAINLESS STEEL CONSTRUCTION
  • IP68 PROTECTION
  • SHIELDED CONNECTION CABLE

 

TECHNICAL FEATURES

  • Minimum load cell verification interval: Vmin = EMax / 10000
  • Full Scale Output: 2mV/V +/- 0,1% (1,3mV/V for CPA150)
  • Repeatability: 0,01% F.S.
  • Temperature effect on zero: 0,0014% /°C
  • Temperature effect on full scale output: 0,0013% /°C
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -30°C/+85°C
    * Upon request up to 200°C
  • Creep error after 4 hours: 0,03% F.S.
  • Maximum tolerated excitation voltage: 15 Vdc
  • Input Resistance: 1100 ± 50 Ohm
  • Output Resistance: 1000 ± 10 Ohm
  • Zero Balance: ± 2% F.S.
  • Insulation Resistance: >5000 MOhm
  • Safe Overload: 150% F.S.
  • 6-wire shielded cable, 5 mm diameter:
    – 5 m long for the versions from 150 up to 10000kg
    – 15 m long for the versions from 20000 to 50000kg

 

Wiring Code
Colour Function
METAL SHIELD
GREEN OUTPUT +
VIOLET SENSE +
RED INPUT +
WHITE OUTPUT –
GREY SENSE –
BLACK INPUT –

 

ATEX Version

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40ºC) TX (Ta -20÷+65ºC)
    ATEX II 1D tD A20 TXºC (Ta -20÷+40ºC) TXºC (Ta -20÷+65ºC).
    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • The CCATEX certificate is issued after the checks done by qualified technicians, with the help of specific equipments, for each load cell.
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

Additional information

Model

CPA150, CPA300, CPA500, CPA1000, CPA2000, CPA3000, CPA5000, CPA7000, CPA10000, CPA20000, CPA30000, CPA50000

Max (kg)

150, 300, 500, 1000, 2000, 3000, 5000, 7000, 10000, 20000, 30000, 50000